CODESYS
Download area for the CODESYS application for installation on powerIO Device. A Guide for installation and management of the application can be found on the help page.
Current version
4.3 - CODESYS versions
Release Date: 09/08/2025
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Changes:
DNS changes from the device are adopted in CODESYS without restarting the application
New CODESYS runtime versions 4.15.0.0, 4.16.0.0 and 4.17.0.0
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
Older versions
4.1 - CODESYS versions
Release Date: 02/04/2025
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Changes:
It is now ensured that when used with the T1.B100 device the serial ports are available before the runtime starts - More information.
The serial ports now correspond to the correct designation without offset. Previously the port had to be specified with an offset of +1. That means port 1 is now also port 1 and not port 2 in CODESYS.
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
4.0 - CODESYS versions
Release Date: 01/28/2025
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Changes:
When used with the powerIO box T1.B100, a serial port can now be assigned to the application. More information.
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
3.9 - CODESYS versions
Release Date: 01/14/2025
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Bug fixes:
New CODESYS runtime added: 4.13.0.0 and 4.14.0.0
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
3.8 - CODESYS versions
Release Date: 11/14/2024
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Bug fixes:
Fixed an issue where after a restart due to an exception the license was no longer connected.
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
3.7 - CODESYS versions
Release Date: 08/06/2024
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Bug fixes:
Support for the new CODESYS runtime version 4.12.0.0
Support for Integration with the CODESYS Automation Server
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
3.6 - CODESYS versions
Release Date: 06/04/2024
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Bug fixes:
Bug fix in a description file
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
3.5 - CODESYS versions
Release Date: 05/13/2024
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Bug fixes:
When a CODESYS exception occurred, a bug was fixed that prevented the execution of the CODESYS function
OnExceptionWrapper(Info Exceptions CODESYS) from executing.
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
3.4 - CODESYS versions
Release Date: 05/08/2024
Standard licensing - Pi MC (delivery state)
Info: This is the standard variant!
** This version is not compatible with the H1.M200 device.
Application-based licensing - Linux Arm MC
Info: Only use this version if you use your own runtime licenses with application-based licenses.
Changes:
Security improvement through non-privileged Docker containers
Update to a more stable base image
If important services like Codesys Control fail, the affected containers are automatically stopped to avoid issues and restarted.
Stability improvements in CODESYS
A new default configuration entry makes using BACnet libraries easier.
Support for multiple configuration files makes updates easier and more flexible.
Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100
Please note that the version(s) listed below are only suitable for the firmware < 3.9 are suitable
Please note that the version(s) listed below are only suitable for the firmware < 3.0 are suitable
3.2 - CODESYS versions
Release Date: 09/08/2023
Download links
Bug fixes
When used with an LTE modem, it can occur that with mapped network adapters the IP settings cannot be set in CODESYS.
Minimum firmware version: v3.0 Compatible devices: H1.M100, H1.M200 and T1.B100
3.1 - CODESYS versions
Release Date: 08/22/2023
Download links
New features and changes
Support for CODESYS runtime 4.9.0.0
Minimum firmware version: v3.0 Compatible devices: H1.M100, H1.M200 and T1.B100
3.0 - CODESYS versions
Release Date: 06/22/2023
Download links
New features and changes
Support for CODESYS runtime 4.8.0.0
Compatibility for H1.M200 powerIO Device
If the application is present in the uploaded area and is activated, the application will be restored after a firmware update and all persistent data, as well as the CODESYS application itself, will be retained.
Dynamic link for visualization in navigation area
Possibility to customize the CODESYSControl_User.cfg file to make individual changes
Minimum firmware version: v3.0 Compatible devices: H1.M100, H1.M200 and T1.B100
Please note that the version(s) listed below are only suitable for the firmware < 3.0 are suitable
Last updated