CODESYS

Download area for the CODESYS Application for installation on powerIO Device. A instructions for installation and management of the Application can be found on the help page.

Current version

chevron-right4.3 - CODESYS versionshashtag

Release Date: 08.09.2025

Standard licensing - Pi MC (as delivered)

Info: This is the standard version!

** This version is not compatible with the H1.M200 device.

Application-based licensing - Linux Arm MC

Info: Only use this version if you use your own runtime licenses with application-based licenses.

Changes:

  • DNS changes from the device are applied in CODESYS without restarting the Application

  • New CODESYS Runtime versions 4.15.0.0, 4.16.0.0 and 4.17.0.0


Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100


Older versions

chevron-right4.1 - CODESYS versionshashtag

Release Date: 04.02.2025

Standard licensing - Pi MC (as delivered)

Info: This is the standard version!

** This version is not compatible with the H1.M200 device.

Application-based licensing - Linux Arm MC

Info: Only use this version if you use your own runtime licenses with application-based licenses.

Changes:

  • It is now ensured that when used with the T1.B100 device, the serial ports are available before the runtime starts - Further information.

  • The serial ports now have the correct name without offset. Previously, the port had to be specified with an offset of +1. That means Port 1 is now also Port 1 and not Port 2 in CODESYS.


Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100

chevron-right4.0 - CODESYS versionshashtag

Release Date: 28.01.2025

Standard licensing - Pi MC (as delivered)

Info: This is the standard version!

** This version is not compatible with the H1.M200 device.

Application-based licensing - Linux Arm MC

Info: Only use this version if you use your own runtime licenses with application-based licenses.

Changes:

  • When used with the powerIO-Box T1.B100, a serial port can now be assigned to the Application. Further information.


Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100

chevron-right3.9 - CODESYS versionshashtag
chevron-right3.8 - CODESYS versionshashtag
chevron-right3.7 - CODESYS versionshashtag
chevron-right3.6 - CODESYS versionshashtag
chevron-right3.5 - CODESYS versionshashtag
chevron-right3.4 - CODESYS versionshashtag

Release Date: 08.05.2024

Standard licensing - Pi MC (as delivered)

Info: This is the standard version!

** This version is not compatible with the H1.M200 device.

Application-based licensing - Linux Arm MC

Info: Only use this version if you use your own runtime licenses with application-based licenses.

Changes:

  • Security improvement through non-privileged Docker containers

  • Update to a more stable base image

  • If important services such as Codesys Control fail, the affected containers are automatically stopped to avoid issues and restarted.

  • Stability improvements in CODESYS

  • A new default configuration entry makes it easier to use BACnet libraries.

  • Support for multiple configuration files makes updates easier and more flexible.


Minimum firmware version: v3.9 Compatible devices: H1.M100, H1.M200 and T1.B100

circle-exclamation
chevron-right3.2 - CODESYS versionshashtag

Release Date: 08.09.2023

Download Links

Bug fixes

  • When used with an LTE modem, it may happen that the IP settings cannot be set in CODESYS for mapped network adapters.


Minimum firmware version: v3.0 Compatible devices: H1.M100, H1.M200 and T1.B100

chevron-right3.1 - CODESYS versionshashtag

Release Date: 22.08.2023

Download Links

New functions and changes

  • Support for CODESYS Runtime 4.9.0.0


Minimum firmware version: v3.0 Compatible devices: H1.M100, H1.M200 and T1.B100

chevron-right3.0 - CODESYS versionshashtag

Release Date: 22.06.2023

Download Links

New functions and changes

  • Support for CODESYS Runtime 4.8.0.0

  • Compatibility for H1.M200 powerIO Device

  • If the Application is present and activated in the uploaded area, then the Application is restored after a firmware update and all persistent data, as well as the CODESYS application itself, remain preserved.

  • Dynamic link for visualization in the navigation area

  • Possibility to customize the CODESYSControl_User.cfg file in order to make individual changes


Minimum firmware version: v3.0 Compatible devices: H1.M100, H1.M200 and T1.B100

circle-exclamation
chevron-right2.1 - CODESYS versionshashtag

Release Date 06.04.2023

Download Links

New functions and changes

  • Support for CODESYS Runtime 4.7.0.0


Minimum version: >= v2.0 < v3.0 Compatible devices: H1.M100 and T1.B100

Last updated