# TRANE\_SYMBIO\_800\_RTWF\_RTSF

## `TRANE_SYMBIO_800_RTWF_RTSF` (FB)

`FUNCTION_BLOCK` TRANE\_SYMBIO\_800\_RTWF\_RTSF

### Darstellung

<figure><img src="/files/lS7g3mVglIeumsOnRw4Y" alt=""><figcaption></figcaption></figure>

InOut:

| Scope       | Name                | Type                                                                           | Initial     | Comment                                                                                                                                                  |
| ----------- | ------------------- | ------------------------------------------------------------------------------ | ----------- | -------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Input       | `xEn`               | `BOOL`                                                                         | TRUE        | Freigabe / Sperrung der Kommunikation (TRUE = Freigabe)                                                                                                  |
| Input       | `byUnitId`          | `BYTE`                                                                         | 0           | Adresse des Geräts                                                                                                                                       |
| Input       | `rBASSetpTemp`      | `REAL`                                                                         | 7.0         | Aktuelle Soll-Temperatur in Grad Celsius (AI 10100)                                                                                                      |
| Input       | `rBASDemLimSetp`    | `REAL`                                                                         | 120.0       | <p>Aktueller Sollwert für die Anforderungs-Grenze in Prozent (<br>AI 10101)</p>                                                                          |
| Input       | `xBASReset`         | `BOOL`                                                                         | FALSE       | <p>Rücksetzung der Fehler der Einheit durch die übergeordnete<br>Steuerung (bei jeder ansteigenden Flanke) (BV 10101)</p>                                |
| Input       | `rBASMode`          | `REAL`                                                                         | 1.0         | <p>Funktionsstatus der Einheit (1.0 = Kühlen, 2.0 = Heizen,<br>3.0 = Abtauen, 4.0 = Freie Kühlung) (MV 10100)</p>                                        |
| Input       | `xUpdateActual`     | `BOOL`                                                                         | FALSE       | <p>Aktualisierung der Istwerte (bei jeder ansteigenden Flanke<br>)</p>                                                                                   |
| Input       | `xUpdateSetp`       | `BOOL`                                                                         | FALSE       | <p>Aktualisierung der Sollwerte (bei jeder ansteigenden Flanke<br>)</p>                                                                                  |
| Input       | `xResError`         | `BOOL`                                                                         | FALSE       | <p>Reinitialisierung der Ausgänge <code>eErrorCodeCom</code> auf dem<br>fehlerfreien Zustand (bei jeder ansteigenden Flanke)</p>                         |
| Inout       | `ModbusClient`      | `ModbusClientBase`                                                             |             | Client des Geräts                                                                                                                                        |
| Output      | `arrIstwerte_0`     | `ARRAY` \[10 .. 15] `OF` `REAL`                                                |             | <p>Array für die Istwerte 0 - Register 10 - 21 - Istwerte -<br>Teil 1 - Analog Inputs (FC04)</p>                                                         |
| Output      | `arrIstwerte_1`     | `ARRAY` \[24 .. 29] `OF` `REAL`                                                |             | <p>Array für die Istwerte 1 - Register 24 - 35 - Istwerte -<br>Teil 2 - Analog Inputs (FC04)</p>                                                         |
| Output      | `arrIstwerte_2`     | `ARRAY` \[38 .. 46] `OF` `REAL`                                                |             | <p>Array für die Istwerte 2 - Register 38 - 55 - Istwerte -<br>Teil 3 - Analog Inputs (FC04)</p>                                                         |
| Output      | `arrIstwerte_3`     | `ARRAY` \[58 .. 118] `OF` `REAL`                                               |             | <p>Array für die Istwerte 3 - Register 58 - 179 - Istwerte -<br>Teil 4 - Analog Inputs (FC04)</p>                                                        |
| Output      | `arrIstwerte_4`     | `ARRAY` \[180 .. 185] `OF` `REAL`                                              |             | <p>Array für die Istwerte 4 - Register 180 - 191 - Istwerte -<br>Teil 5 - Analog Inputs (FC04)</p>                                                       |
| Output      | `arrIstwerte_5`     | `ARRAY` \[10 .. 12] `OF` `REAL`                                                |             | <p>Array für die Istwerte 5 - Register 10 - 15 - Analog Values<br>(FC03)</p>                                                                             |
| Output      | `arxIstwerte_6`     | <p><code>ARRAY</code> \[3010 .. 3045] <code>OF</code><br><code>BOOL</code></p> |             | <p>Array für die Istwerte 6 - Register 3010 - 3045 - Binary<br>Inputs (FC04)</p>                                                                         |
| Output      | `arxIstwerte_7`     | <p><code>ARRAY</code> \[3010 .. 3014] <code>OF</code><br><code>BOOL</code></p> |             | <p>Array für die Istwerte 7 - Register 3010 - 3014 - Binary<br>Values (FC03)</p>                                                                         |
| Output      | `rActSetpTemp`      | `REAL`                                                                         |             | Aktuelle Soll-Temperatur in Grad Celsius (AI 10100)                                                                                                      |
| Output      | `rActDemLimSetp`    | `REAL`                                                                         |             | <p>Aktueller Sollwert für die Anforderungs-Grenze in Prozent (<br>AI 10101)</p>                                                                          |
| Output      | `rEvapEntTemp`      | `REAL`                                                                         |             | <p>Aktuelle kaltwasserseitige Eintrittstemperatur in Grad<br>Celsius (AI 10102)</p>                                                                      |
| Output      | `rEvapLeavTemp`     | `REAL`                                                                         |             | <p>Aktuelle kaltwasserseitige Austrittstemperatur in Grad<br>Celsius (AI 10103)</p>                                                                      |
| Output      | `rOutsideTemp`      | `REAL`                                                                         |             | Aktuelle Aussentemperatur in Grad Celsius (AI 10104)                                                                                                     |
| Output      | `rActRunCapacity`   | `REAL`                                                                         |             | Aktuelle Betriebskapazität in Prozent (AI 10108)                                                                                                         |
| Output      | `rCondEntTemp`      | `REAL`                                                                         |             | <p>Aktuelle warmwasserseitige Eintrittstemperatur in Grad<br>Celsius (AI 10144)</p>                                                                      |
| Output      | `rCondLeavTemp`     | `REAL`                                                                         |             | <p>Aktuelle warmwasserseitige Austrittstemperatur in Grad<br>Celsius (AI 10145)</p>                                                                      |
| Output      | `rPowerConsumpt`    | `REAL`                                                                         |             | <p>Aktuelle elektrische Leistungaufnahme der Einheit in kW (AI<br>10146)</p>                                                                             |
| Output      | `rUnitSourceID`     | `REAL`                                                                         |             | Aktueller Diagnose-Code der Einheit (AI 10187)                                                                                                           |
| Output      | `rActChiSetpTemp`   | `REAL`                                                                         |             | <p>Aktuelle Soll-Temperatur - Kühlbetrieb - in Grad Celsius (<br>AI 10189)</p>                                                                           |
| Output      | `rActHotSetpTemp`   | `REAL`                                                                         |             | <p>Aktuelle Soll-Temperatur - Heizbetrieb - in Grad Celsius (<br>AI 10190)</p>                                                                           |
| Output      | `xRunEnable`        | `BOOL`                                                                         |             | <p>Betriebsbereitschaft (FALSE = keine, TRUE = aktiv)(BI<br>10100)</p>                                                                                   |
| Output      | `xChilRunState`     | `BOOL`                                                                         |             | <p>Primäre Betriebsart der Kühlsequenz (FALSE = Aus, TRUE = Ein<br>)(BI 10103)</p>                                                                       |
| Output      | `xEmergencyStop`    | `BOOL`                                                                         |             | <p>Status des Not-Aus (FALSE = Auto, TRUE = Not-Aus aktiv)(<br>BI 10106)</p>                                                                             |
| Output      | `xEvaFlowState`     | `BOOL`                                                                         |             | <p>Status der Strömung des Kaltwassers (FALSE = keine<br>Strömung, TRUE = Strömung)(BI 10107)</p>                                                        |
| Output      | `xDiagShutdwPres`   | `BOOL`                                                                         |             | <p>Status der Abschaltens der Einheit (FALSE = Normal, TRUE =<br>Störung)(BI 10109)</p>                                                                  |
| Output      | `xDiagManResPres`   | `BOOL`                                                                         |             | <p>Status des manuellen Resets der Einheit (FALSE = Normal,<br>TRUE = Störung)(BI 10110)</p>                                                             |
| Output      | `xComp1ARunState`   | `BOOL`                                                                         |             | <p>Status des Betriebs von Kompressor 1A (FALSE = Stop, TRUE =<br>Auto) (BI 10116)</p>                                                                   |
| Output      | `xComp1BRunState`   | `BOOL`                                                                         |             | <p>Status des Betriebs von Kompressor 1B (FALSE = Stop, TRUE =<br>Auto) (BI 10117)</p>                                                                   |
| Output      | `xComp2ARunState`   | `BOOL`                                                                         |             | <p>Status des Betriebs von Kompressor 2A (FALSE = Stop, TRUE =<br>Auto) (BI 10118)</p>                                                                   |
| Output      | `xComp2BRunState`   | `BOOL`                                                                         |             | <p>Status des Betriebs von Kompressor 2B (FALSE = Stop, TRUE =<br>Auto) (BI 10119)</p>                                                                   |
| Output      | `xExtAutoStop`      | `BOOL`                                                                         |             | <p>Status der externen Sperrung der Einheit (FALSE = Stop,<br>TRUE = Auto) (BI 10120)</p>                                                                |
| Output      | `xCondWaterPump`    | `BOOL`                                                                         |             | <p>Status des Betriebs der Umwälzpumpe im Kaltwasserkreis (<br>FALSE = Aus, TRUE = Ein) (BI 10121)</p>                                                   |
| Output      | `xEvaWaterPump`     | `BOOL`                                                                         |             | <p>Status des Betriebs der Umwälzpumpe im Warmwasserkreis (<br>FALSE = Aus, TRUE = Ein) (BI 10122)</p>                                                   |
| Output      | `xCondFlowState`    | `BOOL`                                                                         |             | <p>Status der Strömung des Warmwassers (FALSE = keine<br>Strömung, TRUE = Strömung)(BI 10123)</p>                                                        |
| Output      | `xFrontAutoStop`    | `BOOL`                                                                         |             | <p>Status der Sperrung der Einheit durch die Bedienung am Gerät<br>(FALSE = Stop, TRUE = Auto) (BI 10124)</p>                                            |
| Output      | `xAlmLatchGen`      | `BOOL`                                                                         |             | <p>Status des generellen selbhaltenden Alarms (FALSE = Normal,<br>TRUE = Störung) (BI 10130)</p>                                                         |
| Output      | `xBASAutoStop`      | `BOOL`                                                                         |             | <p>Status der Sperrung der Einheit durch die übergeordnete<br>Steuerung (FALSE = Stop, TRUE = Auto) (BV 10100)</p>                                       |
| Output      | `xBASDiagReset`     | `BOOL`                                                                         |             | <p>Status der Rücksetzung der Fehler der Einheit durch die<br>übergeordnete Steuerung (FALSE = Normal, TRUE = Reset) (<br>BV 10101)</p>                  |
| Output      | `xBASComp1ALock`    | `BOOL`                                                                         |             | <p>Status der Abschaltung von Kompressor 1A durch die<br>übergeordnete Steuerung (FALSE = Normal, TRUE = Sperrung)<br>(BV 10106)</p>                     |
| Output      | `xBASComp1BLock`    | `BOOL`                                                                         |             | <p>Status der Abschaltung von Kompressor 1B durch die<br>übergeordnete Steuerung (FALSE = Normal, TRUE = Sperrung)<br>(BV 10107)</p>                     |
| Output      | `xBASComp2ALock`    | `BOOL`                                                                         |             | <p>Status der Abschaltung von Kompressor 2A durch die<br>übergeordnete Steuerung (FALSE = Normal, TRUE = Sperrung)<br>(BV 10108)</p>                     |
| Output      | `xBASComp2BLock`    | `BOOL`                                                                         |             | <p>Status der Abschaltung von Kompressor 2B durch die<br>übergeordnete Steuerung (FALSE = Normal, TRUE = Sperrung)<br>(BV 10109)</p>                     |
| Output      | `xBASEvaWaterPump`  | `BOOL`                                                                         |             | <p>Status der Anforderung der Umwälzpumpe im Warmwasserkreis<br>durch die übergeordnete Steuerung (FALSE = Auto, TRUE = Ein<br>) (BV 10110)</p>          |
| Output      | `xBASConWaterPump`  | `BOOL`                                                                         |             | <p>Status der Anforderung der Umwälzpumpe im Kaltwasserkreis<br>durch die übergeordnete Steuerung (FALSE = Auto, TRUE = Ein<br>) (BV 10111)</p>          |
| Output      | `rRunMode`          | `REAL`                                                                         |             | <p>Betriebsstatus der Einheit (1.0 = Aus, 2.0 = Start, 3.0 =<br>Run, 4.0 = Pre-Shutdown, 5.0 = Service, Informationen nicht<br>gesichert) (MI 10100)</p> |
| Output      | `rOperatingMode`    | `REAL`                                                                         |             | <p>Funktionsstatus der Einheit (1.0 = Kühlen, 2.0 = Heizen,<br>3.0 = Abtauen, 4.0 = Freie Kühlung) (MI 10101)</p>                                        |
| Output      | `rBASOperatMode`    | `REAL`                                                                         |             | <p>Funktionsstatus der Einheit durch die übergeordnete<br>Steuerung (1.0 = Kühlen, 2.0 = Heizen, 3.0 = Abtauen, 4.0 =<br>Freie Kühlung) (MV 10100)</p>   |
| Output      | `xAlarm`            | `BOOL`                                                                         | FALSE       | Sammelstörung (TRUE = Störung)                                                                                                                           |
| Output      | `xAlarmCom`         | `BOOL`                                                                         | FALSE       | Sammelstörung - Kommunikation (TRUE = Störung)                                                                                                           |
| Output      | `eErrorCodeCom`     | ModbusErrorCode                                                                |             | Fehlercode - Kommunikation (0 = kein Fehler)                                                                                                             |
| Output      | `xBusy`             | `BOOL`                                                                         |             | Kommunikationsanzeige (TRUE = Kommunikation)                                                                                                             |
| Input Const | `diAdrOffset`       | `DINT`                                                                         | 0           | <p>Offset zur Berechnung der Modbus-Adressen (aus den Modbus-<br>Registern) (Zulässiger Bereich: -1, 0, +1)</p>                                          |
| Input Const | `tTimeUpdateSetp`   | `TIME`                                                                         | TIME#45s0ms | <p>Updateintervall für die Vorgänge, die durch den Eingang<br><code>xUpdateSetp</code> beeinflusst werden</p>                                            |
| Input Const | `tTimeUpdateActual` | `TIME`                                                                         | TIME#10s0ms | <p>Updateintervall für die Vorgänge, die durch den Eingang<br><code>xUpdateActual</code> beeinflusst werden</p>                                          |


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://support.powerio.com/hub/codesys-hvac/hvac-modbus-library/functionblocks/trane/trane_symbio_800_rtwf_rtsf.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.