> For the complete documentation index, see [llms.txt](https://support.powerio.com/hub/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://support.powerio.com/hub/codesys-hvac/hvac-modbus-library/functionblocks/powerio/powerio_t1_b100_full.md).

# POWERIO\_T1\_B100\_FULL

## `POWERIO_T1_B100_FULL` (FB)

`FUNCTION_BLOCK` POWERIO\_T1\_B100\_FULL

### Darstellung

<figure><img src="/files/S0XjQpulLWjKpuLMn3Vd" alt=""><figcaption></figcaption></figure>

InOut:

| Scope       | Name                | Type                           | Initial                                  | Comment                                                                                                                                                             |
| ----------- | ------------------- | ------------------------------ | ---------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Input       | `xEn`               | `BOOL`                         | TRUE                                     | Freigabe / Sperrung der Kommunikation (TRUE = Freigabe)                                                                                                             |
| Input       | `byUnitId`          | `BYTE`                         | 248                                      | Adresse des Geräts                                                                                                                                                  |
| Input       | `xUpdateActual`     | `BOOL`                         | FALSE                                    | <p>Aktualisierung der Istwerte (bei jeder ansteigenden Flanke<br>)</p>                                                                                              |
| Input       | `xResError`         | `BOOL`                         | FALSE                                    | <p>Reinitialisierung der Ausgänge <code>eErrorCodeCom</code> bzw.<br><code>xErrorCodeDev</code> auf dem fehlerfreien Zustand (bei jeder<br>ansteigenden Flanke)</p> |
| Inout       | `ModbusClient`      | `ModbusClientBase`             |                                          | Client des Geräts                                                                                                                                                   |
| Output      | `xLED_RUN`          | `BOOL`                         |                                          | Zustand der LED `RUN` (TRUE = Ein)                                                                                                                                  |
| Output      | `xLED_SSM`          | `BOOL`                         |                                          | Zustand der LED `SSM` (TRUE = Ein)                                                                                                                                  |
| Output      | `xLED_COM`          | `BOOL`                         |                                          | Zustand der LED `COM` (TRUE = Ein)                                                                                                                                  |
| Output      | `sHostName`         | `STRING`                       |                                          | Hostname der Box                                                                                                                                                    |
| Output      | `sBoxName`          | `STRING`                       |                                          | Name der Box                                                                                                                                                        |
| Output      | `sBoxComment`       | `STRING`                       |                                          | Kommentar zur Box                                                                                                                                                   |
| Output      | `sSerialNumber`     | `STRING`                       |                                          | Seriennummer der Box                                                                                                                                                |
| Output      | `sCheckDate`        | `STRING`                       |                                          | Letzes Prüfdatum der Box                                                                                                                                            |
| Output      | `sStartDate`        | `STRING`                       |                                          | Start-Datum der Box                                                                                                                                                 |
| Output      | `sAdapter`          | `STRING`                       |                                          | Adapter-Name der Box                                                                                                                                                |
| Output      | `sLink`             | `STRING`                       |                                          | Link-Name der Box                                                                                                                                                   |
| Output      | `eLinkMode`         | POWERIO\_T1\_B100\_LINK\_MODE  |                                          | Link - Zustand der Box (1 = Link aktiv)                                                                                                                             |
| Output      | `eIPMode`           | POWERIO\_T1\_B100\_IP\_MODE    |                                          | Art der Vergabe der IP-Adresse der Box (1 = DHCP)                                                                                                                   |
| Output      | `sMode`             | `STRING`                       |                                          | Modus-Name der Box                                                                                                                                                  |
| Output      | `sMACAdr`           | `STRING`                       |                                          | MAC-Adresse der Box                                                                                                                                                 |
| Output      | `sIPAdr`            | `STRING`                       |                                          | IP-Adresse der Box                                                                                                                                                  |
| Output      | `sSubnetMask`       | `STRING`                       |                                          | Subnet-Maske der Box                                                                                                                                                |
| Output      | `sGWAdr`            | `STRING`                       |                                          | Gateway-Adresse der Box                                                                                                                                             |
| Output      | `sDNS1Adr`          | `STRING`                       |                                          | Adresse des DNS 1 der Box                                                                                                                                           |
| Output      | `sDNS2Adr`          | `STRING`                       |                                          | Adresse des DNS 2 der Box                                                                                                                                           |
| Output      | `sBroadcastAdr`     | `STRING`                       |                                          | Broadcast-Adresse der Box                                                                                                                                           |
| Output      | `rCPU_Workload`     | `REAL`                         |                                          | Auslastung der CPU in Prozent                                                                                                                                       |
| Output      | `rRAM_Usage`        | `REAL`                         |                                          | Aktuell genutzte RAM - Kapazität in MB                                                                                                                              |
| Output      | `rTemp_CPU`         | `REAL`                         |                                          | Temperatur der CPU                                                                                                                                                  |
| Output      | `rTemp_Sys_1`       | `REAL`                         |                                          | Temperatur des Sys 1 - Chips                                                                                                                                        |
| Output      | `rTemp_Sys_2`       | `REAL`                         |                                          | Temperatur der Sys 2 - 5V                                                                                                                                           |
| Output      | `rTemp_CM`          | `REAL`                         |                                          | Temperatur des CM                                                                                                                                                   |
| Output      | `rU_24V`            | `REAL`                         |                                          | Spannung der 24VDC-Versorgung                                                                                                                                       |
| Output      | `rP_24V`            | `REAL`                         |                                          | Elektrische Leistung der 24VDC-Versorgung                                                                                                                           |
| Output      | `rI_24V`            | `REAL`                         |                                          | Strom der 24VDC-Versorgung                                                                                                                                          |
| Output      | `rU_5V_CAP`         | `REAL`                         |                                          | Spannung des 5V - Kondensator (USV - Funktion)                                                                                                                      |
| Output      | `rU_3_3V`           | `REAL`                         |                                          | Spannung der 3.3V - Versorgung                                                                                                                                      |
| Output      | `rU_3_3V_CM`        | `REAL`                         |                                          | Spannung der 3.3V - Versorgung - CM                                                                                                                                 |
| Output      | `rU_1_8V_CM`        | `REAL`                         |                                          | Spannung der 1.8V - Versorgung - CM                                                                                                                                 |
| Output      | `arbyLED_STATE`     | `ARRAY` \[0 .. 17] `OF` `BYTE` |                                          | Zustand aller Status - LED’s (0 = AUS, 1 = EIN)                                                                                                                     |
| Output      | `eMode_Port_1`      | POWERIO\_T1\_B100\_PORT\_MODE  |                                          | Betriebsart von Port 1 (1 = RSxxx, 2 = Modbus)                                                                                                                      |
| Output      | `eMode_Port_2`      | POWERIO\_T1\_B100\_PORT\_MODE  |                                          | Betriebsart von Port 2 (1 = RSxxx, 2 = Modbus)                                                                                                                      |
| Output      | `eMode_Port_3`      | POWERIO\_T1\_B100\_PORT\_MODE  |                                          | Betriebsart von Port 3 (1 = RSxxx, 2 = Modbus)                                                                                                                      |
| Output      | `eMode_Port_4`      | POWERIO\_T1\_B100\_PORT\_MODE  |                                          | Betriebsart von Port 4 (1 = RSxxx, 2 = Modbus)                                                                                                                      |
| Output      | `eMode_Port_5`      | POWERIO\_T1\_B100\_PORT\_MODE  |                                          | Betriebsart von Port 5 (1 = RSxxx, 2 = Modbus)                                                                                                                      |
| Output      | `ltUpTime`          | `LTIME`                        |                                          | Betriebsdauer seit dem letzten Neustart                                                                                                                             |
| Output      | `xAlarm`            | `BOOL`                         | FALSE                                    | Sammelstörung (TRUE = Störung)                                                                                                                                      |
| Output      | `xAlarmCom`         | `BOOL`                         | FALSE                                    | Sammelstörung - Kommunikation (TRUE = Störung)                                                                                                                      |
| Output      | `eErrorCodeCom`     | ModbusErrorCode                |                                          | Fehlercode - Kommunikation (0 = kein Fehler)                                                                                                                        |
| Output      | `eErrorCodeDev`     | POWERIO\_T1\_B100\_ERROR\_CODE | POWERIO\_T1\_B100\_ERROR\_CODE.NO\_ERROR | Fehlercode - Gerät (0 = kein Fehler)                                                                                                                                |
| Output      | `xBusy`             | `BOOL`                         |                                          | Kommunikationsanzeige (TRUE = Kommunikation)                                                                                                                        |
| Input Const | `tTimeUpdateActual` | `TIME`                         | TIME#5m0s0ms                             | <p>Updateintervall für die Vorgänge, die durch den Eingang<br><code>xUpdateActual</code> beeinflusst werden</p>                                                     |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://support.powerio.com/hub/codesys-hvac/hvac-modbus-library/functionblocks/powerio/powerio_t1_b100_full.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.