# Wilo\_ControlStat

## `Wilo_ControlStat` (`ENUM`)

`TYPE` Wilo\_ControlStat: gen\_speed

Attributes: `qualified_only`

InOut:

| Name              | Initial | Comment                                                                                                                    |
| ----------------- | ------- | -------------------------------------------------------------------------------------------------------------------------- |
| gen\_speed        | 1       | constant speed                                                                                                             |
| CONST\_FREQ       | 2       | reserved                                                                                                                   |
| Gen\_PHdConst     | 3       | constant differential pressure                                                                                             |
| Gen\_PHdVar       | 4       | differential pressure which varies with the flow                                                                           |
| CONST\_PRESSURE   | 5       | constant discharge pressure                                                                                                |
| TEMP\_VARIABLE    | 6       | <p>differential pressure which varies with the fluid<br>temperature</p>                                                    |
| CONST\_HEAD       | 7       | reserved                                                                                                                   |
| CONST\_FLOW       | 8       | reserved                                                                                                                   |
| Gen\_T            | 9       | constant temperature for generic application                                                                               |
| Gen\_TDiff        | 10      | constant differential temperature for generic application                                                                  |
| CONST\_LEV        | 11      | reserved                                                                                                                   |
| Invalid           | 15      | Invalid value                                                                                                              |
| HeatRadiator\_PHd | 16      | <p>differential pressure which varies with the flow for heating<br>radiator applications</p>                               |
| HeatRadiator\_DA  | 17      | <p>automatic setpoint adjustement (dynamic adapt) for heating<br>radiator applications</p>                                 |
| HeatRadiator\_T   | 18      | constant temperature for heating radiator applications                                                                     |
| HeatFloor\_PHd    | 19      | <p>differential pressure which varies with the flow for floor<br>heating applications</p>                                  |
| HeatFloor\_DA     | 20      | <p>automatic setpoint adjustement (dynamic adapt) for floor<br>heating applications</p>                                    |
| HeatFloor\_T      | 21      | constant temperature for floor heating applications                                                                        |
| HeatCeiling\_PHd  | 22      | <p>constant differential pressure for ceiling heating<br>applications</p>                                                  |
| HeatCeiling\_DA   | 23      | <p>automatic setpoint adjustment (dynamic adapt) for ceiling<br>heating applications</p>                                   |
| HeatCeiling\_T    | 24      | constant temperature for ceiling heating applications                                                                      |
| HeatFan\_PHd      | 25      | <p>differential pressure which varies with the flow for fan<br>coil heating applications</p>                               |
| HeatFan\_DA       | 26      | <p>automatic setpoint adjustement (dynamic adapt) for fan coil<br>heating applications</p>                                 |
| HeatFan\_T        | 27      | constant temperature for fan coil heating applications                                                                     |
| HeatB\_T          | 28      | <p>constant temperature for heating applications with hydraulic<br>separator</p>                                           |
| HeatB\_TDiff      | 29      | <p>constant differential temperature for heating applications<br>with hydraulic separator</p>                              |
| HeatB\_AccFlow    | 30      | <p>setpoint depending on the volume flow of other pumps for<br>heating applications with hydraulic separator</p>           |
| HeatE\_T          | 31      | <p>constant temperature for heating applications with heat<br>exchanger</p>                                                |
| HeatE\_TDiff      | 32      | <p>constant differential temperature for heating applications<br>with heat exchanger</p>                                   |
| HeatE\_AccFlow    | 33      | <p>setpoint depending on the volume flow of other pumps for<br>heating applications with heat exchanger</p>                |
| Heat\_PHdConst    | 34      | constant differential pressure for heating applications                                                                    |
| Heat\_PHdVar      | 35      | <p>differential pressure which varies with the flow for heating<br>applications</p>                                        |
| Heat\_PHdExt      | 36      | <p>constant differential pressure for heating applications with<br>external differential pressure sensor</p>               |
| Heat\_DA          | 37      | <p>automatic setpoint adjustement (dynamic adapt) for heating<br>applications</p>                                          |
| Heat\_VolFlow     | 38      | constant volume flow for heating applications                                                                              |
| Heat\_AccFlow     | 39      | <p>setpoint depending on the volume flow of other pumps for<br>heating applications</p>                                    |
| Heat\_T           | 40      | constant temperature for heating applications                                                                              |
| Heat\_TDiff       | 41      | constant differential temperature for heating applications                                                                 |
| Heat\_Spd         | 42      | constant speed for heating applications                                                                                    |
| CoolCeiling\_PHd  | 43      | <p>constant differential pressure for ceiling cooling<br>applications</p>                                                  |
| CoolCeiling\_DA   | 44      | <p>automatic setpoint adjustment (dynamic adapt) for ceiling<br>cooling applications</p>                                   |
| CoolCeiling\_T    | 45      | constant temperature for ceiling cooling applications                                                                      |
| CoolFloor\_PHd    | 46      | <p>constant differential pressure for floor cooling<br>applications</p>                                                    |
| CoolFloor\_DA     | 47      | <p>automatic setpoint adjustment (dynamic adapt) for floor<br>cooling applications</p>                                     |
| CoolFloor\_T      | 48      | constant temperature for floor cooling applications                                                                        |
| CoolFan\_PHd      | 49      | <p>differential pressure which varies with the flow for fan<br>coil cooling applications</p>                               |
| CoolFan\_DA       | 50      | <p>automatic setpoint adjustement (dynamic adapt) for fan coil<br>cooling applications</p>                                 |
| CoolFan\_T        | 51      | constant temperature for fan coil cooling applications                                                                     |
| CoolB\_T          | 52      | <p>constant temperature for cooling applications with hydraulic<br>separator</p>                                           |
| CoolB\_TDiff      | 53      | <p>constant differential temperature for cooling applications<br>with hydraulic separator</p>                              |
| CoolB\_AccFlow    | 54      | <p>setpoint depending on the volume flow of other pumps for<br>cooling applications with hydraulic separator</p>           |
| CoolE\_T          | 55      | <p>constant temperature mode for cooling applications with heat<br>exchanger</p>                                           |
| CoolE\_TDiff      | 56      | <p>constant differential temperature for cooling applications<br>with heat exchanger</p>                                   |
| CoolE\_AccFlow    | 57      | <p>setpoint depending on the volume flow of other pumps for<br>cooling applications with heat exchanger</p>                |
| Cool\_PHdConst    | 58      | constant differential pressure for cooling applications                                                                    |
| Cool\_PHdVar      | 59      | <p>differential pressure which varies with the flow for cooling<br>applications</p>                                        |
| Cool\_PHdExt      | 60      | <p>constant differential pressure for cooling applications with<br>external differential pressure sensor</p>               |
| Cool\_DA          | 61      | <p>automatic setpoint adjustement (dynamic adapt) for cooling<br>applications</p>                                          |
| Cool\_VolFlow     | 62      | constant volume flow for cooling applications                                                                              |
| Cool\_AccFlow     | 63      | <p>setpoint depending on the volume flow of other pumps for<br>cooling applications</p>                                    |
| Cool\_T           | 64      | constant temperature mode for cooling applications                                                                         |
| Cool\_TDiff       | 65      | constant differential temperature for cooling applications                                                                 |
| Cool\_Spd         | 66      | constant speed for cooling applications                                                                                    |
| San\_Circ\_T      | 67      | constant temperature for sanitary hot water circulation                                                                    |
| SanWHeat\_TDiff   | 68      | <p>constant differential temperature for sanitary hot water<br>application with heat exchanger in the storage tank</p>     |
| SanLS\_T          | 69      | reserved                                                                                                                   |
| SanLS\_AccFlow    | 70      | reserved                                                                                                                   |
| San\_PHdConst     | 71      | <p>constant differential pressure for sanitary hot water<br>applications</p>                                               |
| San\_PHdVar       | 72      | <p>differential pressure which varies with the flow for<br>sanitary hot water applications</p>                             |
| San\_PHdExt       | 73      | <p>constant differential pressure for sanitary hot water<br>applications with external differential pressure sensor</p>    |
| San\_VolFlow      | 74      | constant volume flow for sanitary hot water applications                                                                   |
| San\_AccFlow      | 75      | <p>setpoint depending on the volume flow of other pumps for<br>sanitary hot water applications</p>                         |
| San\_T            | 76      | constant temperature for sanitary hot water applications                                                                   |
| San\_TDiff        | 77      | <p>constant differential temperature for sanitary hot water<br>applications</p>                                            |
| San\_Spd          | 78      | constant speed for sanitary hot water applications                                                                         |
| Gen\_PHdExt       | 79      | <p>constant differential pressure for generic applications with<br>external differential pressure sensor</p>               |
| Gen\_DA           | 80      | <p>automatic setpoint adjustement (dynamic adapt) for generic<br>applications</p>                                          |
| Gen\_VolFlow      | 81      | constant volume flow for generic applications                                                                              |
| Gen\_AccFlow      | 82      | <p>setpoint depending on the volume flow of other pumps for<br>generic applications</p>                                    |
| ScndPHdConst      | 83      | <p>constant differential pressure. A special parameter set<br>which ist stored in the device is used</p>                   |
| ScndPHdVar        | 84      | <p>differential pressure which varies with the flow. A special<br>parameter set which ist stored in the device is used</p> |
| ScndFlow          | 85      | <p>constant volume flow. A special parameter set which ist<br>stored in the device is used</p>                             |
| ScndSpd           | 86      | <p>constant speed. A special parameter set which ist stored in<br>the device is used</p>                                   |
| VAR\_PRESSURE     | 139     | discharge pressure that varies with the flow                                                                               |
| Gen\_UsrDfd       | 140     | user configurable PID controller                                                                                           |